1000L IBC for Hydrobromic Acid
Looking for a 1000L IBC for Hydrobromic acid? The VARIBOX chemical overview lists Hydrobromic acid for use in VARIBOX reusable IBCs. Hydrobromic acid is referenced as UN 1788, with EPDM as the recommended seal material and a vacuum vent as the specified venting. Always confirm the exact formulation, concentration, temperature and operating conditions before use.
Hydrobromic Acid IBC at a glance
| Chemical | Hydrobromic acid |
|---|---|
| Formula / synonym | HBr (aq); hydrogen bromide solution / hydrobromic acid |
| ADR / UN reference | UN 1788 |
| Recommended VARIBOX seal | EPDM |
| Specified venting | Vacuum vent |
| Permitted period of use | Not more than 5 years from date of manufacture |
| Scope in VARIBOX overview | Aqueous solution; exact concentration to be confirmed |
This page is a product-selection overview, not a substitute for an application-specific chemical compatibility assessment. Confirm the exact formulation, concentration, temperature and operating conditions before use.


Reusable 1000L IBC for Hydrobromic acid
The VARIBOX Single Containment (SC) 1000 is a reusable IBC design. For Hydrobromic acid, confirm the approved chemical configuration, EPDM seal selection, specified venting and exact operating conditions before use.
Double-walled IBC design for Hydrobromic acid
The VARIBOX Full Containment (FC) 1000 is a double-walled IBC design with integrated spill containment. For Hydrobromic acid, confirm that the selected VARIBOX model and chemical configuration are covered by the applicable approval and site requirements before use.

SC 1000 vs FC 1000 for Hydrobromic acid
The VARIBOX SC 1000 and FC 1000 use different containment concepts. The final product choice for Hydrobromic acid must be checked against the applicable chemical approval, site setup and process requirements.
| Selection point | VARIBOX SC 1000 | VARIBOX FC 1000 |
|---|---|---|
| Construction | Reusable single-containment IBC | Reusable double-walled IBC |
| Containment | Use within an approved site setup with the required containment measures | Integrated spill containment |
| Chemical configuration | Confirm EPDM seals, vacuum venting and the approved Hydrobromic acid application before use | |
| Product information | VARIBOX Single Containment | VARIBOX Full Containment |
Do not select an IBC only from the chemical name. Confirm the exact product specification, operating conditions, current approval and site risk assessment.

EPDM configuration for Hydrobromic acid
For the Hydrobromic acid application described in the VARIBOX chemical overview, the recommended seal material is EPDM. Compatibility depends on the exact formulation, concentration, temperature and process conditions. Key overview information:
- Formula / synonym: HBr (aq); hydrogen bromide solution / hydrobromic acid
- ADR / UN reference: UN 1788
- Recommended seal: EPDM
- Specified venting: Vacuum vent
- Permitted period of use: not more than 5 years from date of manufacture
Before choosing an IBC for Hydrobromic acid
The VARIBOX chemical overview lists hydrobromic acid as an aqueous solution. Confirm the exact concentration and full product specification before use. Before choosing a final IBC configuration, confirm:
- Exact chemical name, formulation and concentration
- Minimum and maximum filling, storage and transport temperatures
- Any additives, impurities or mixtures that can affect compatibility
- EPDM seal compatibility for the actual operating conditions
- The specified vacuum vent and any application-specific venting requirements
- Filling and emptying process, valves, couplings and connection requirements
- Site containment, risk assessment and local storage requirements
- Applicable transport documentation and the current chemical approval
- Inspection, cleaning, reuse and return-cycle requirements
See the EPDM or Viton FAQ, review the Chemicals in the VARIBOX overview, or contact VARIBOX for an application-specific check.
Frequently asked questions about Hydrobromic acid IBCs
What UN number applies to Hydrobromic acid?
The VARIBOX chemical overview lists Hydrobromic acid under UN 1788. Confirm the exact transport classification and current documentation for the specific product before transport.
Which seal is recommended for Hydrobromic acid?
The VARIBOX chemical overview recommends EPDM for this application. Final compatibility still depends on the exact formulation and operating conditions.
Which vent is specified?
The overview specifies a vacuum vent. Confirm the complete venting configuration against the current approval and your application before use.
How long can the IBC be used for this chemical application?
The overview states a permitted period of use of not more than five years from the date of manufacture. Inspection, maintenance and other applicable requirements still apply.
Does this page cover every concentration of Hydrobromic acid?
The VARIBOX chemical overview lists hydrobromic acid as an aqueous solution. Confirm the exact concentration and full product specification before use.
How do I confirm the correct VARIBOX configuration?
Provide the exact chemical specification, concentration, temperature range, SDS and process conditions to VARIBOX. The final configuration can then be checked against the applicable approval and your operating requirements.